Enclosed attics and enclosed rafter spaces formed where ceilings are applied directly to the underside of roof rafters shall have cross ventilation for each separate space by ventilating openings protected against the entrance of rain or snow.
Roof ventilation irc 2015.
Between half and two thirds of the provided ventilation shall be installed at the eaves.
The ventilation amount and opening size requirements can be found in section 806 roof ventilation of chapter 8 roof ceiling construction.
Vented attics shall have a minimum net free ventilation area at least 1 300 of the area of the vented space.
Chapter 9 roof assemblies chapter 10 chimneys and fireplaces.
The following are the requirements taken directly from the irc.
R806 roof ventilation r807 attic access.
Unvented attics and unvented enclosed roof framing assemblies created by ceilings that are applied directly to the underside of the roof framing members and structural roof sheathing applied directly to the top of the roof framing members rafters shall be permitted where all the following conditions are met.
The majority of the requirements related to attic ventilation have not changed much from the previous editions.
The ventilation openings shall have a least dimension of 1 16 inch 1 6 mm minimum and 1 4 inch 6 4 mm maximum.
2015 international residential code for attic ventilation air vent inc.
The international code council icc is a non profit organization dedicated to developing model codes and standards used in the design build and compliance process.
R806 5 unvented attic and unvented enclosed rafter assemblies.
International residential code 2015 irc 2015 part i administrative chapter 1 scope and administration part ii definitions chapter 2 definitions part iii building planning and construction.
Air vent provides a complete line of ventilation products that meet the highest standards for quality and performance.